Life After Treatment
Can you have an MRI scan with dental implants? Heating, image distortion and magnetic dentures
A titanium implant is no obstacle to an MRI scan; what really needs attention is magnetic denture attachments and the image of the jaw area
When an MRI scan is requested for a slipped disc, a headache or a knee injury, many people think of the implant in their mouth: is metal pulled by the magnet, does it heat up, does it prevent the scan? The short answer is that a titanium implant is no obstacle to an MRI scan. But there are three details: an implant can cause distortion in images of the head and neck, the parts of removable dentures held in place by a magnet behave differently in a strong magnetic field, and you need to mention your implant before the scan. Below you will find what you need to know for MRI, CT, X-rays and airport security checks.
Short answer
Yes, you can have an MRI scan with dental implants. Titanium is not a metal that is pulled by a magnet, and in measurements implant heating stayed below half a degree in 1.5 and 3 Tesla scanners. The US Food and Drug Administration (FDA) says that implants can distort the image and therefore recommends telling the healthcare team before every MRI scan and X-ray; it also writes that it is not aware of any reported adverse event related to MRI or X-rays. If you use a magnetic removable denture, take the denture out before the scan and separately report the metal keeper on the implant.
- MRI scan
- Can be done with a titanium implant; report it beforehand
- Heating
- Below half a degree in 1.5 and 3 Tesla measurements
- Image
- Distortion around the implant is possible in head, face and neck scans
- Magnetic denture
- Take the denture out; separately mention the steel keeper on the implant
What MRI does to an implant, and what an implant does to MRI
MRI works with two kinds of energy: a strong, static magnetic field and the radio waves sent while the image is being taken. Three questions are asked about a metal in the body: does the magnetic field pull it or twist it, do the radio waves heat it, and does the metal distort the image? The first two are safety questions, the third a diagnostic one. For dental implants the answers differ from one another.
On the question of being pulled, titanium is reassuring. A study in Japan that examined titanium implants in 1.5 and 3 Tesla scanners writes that titanium is paramagnetic, that is, there is no problem of the static magnetic field pulling it. In a study that tested 18 different dental materials in a very powerful research scanner of 7 Tesla, too, implants and top parts showed a deflection of only between 5 and 6.5 degrees; this is a very small effect. In metal crowns made of alloys such as cobalt-chromium and nickel-chromium, the deflection was more pronounced.
On the question of heating, measurements have been made. In the same Japanese study, in a tissue-like model, the temperature of titanium implants rose by 0.4 degrees at most in 1.5 and 3 Tesla scans. In the 7 Tesla study, an implant 50 mm long heated up by as much as 1.5 degrees, particularly in scanning sequences that use high energy; in shorter implants and in top parts the rise was smaller. These measurements were made in models known as phantoms, not directly in the human mouth; for this reason the Japanese authors, too, recommend that the scan be carried out with care.
This is why long implants deserve a separate mention. Zygomatic implants, which extend to the cheekbone, and some strategic implants that anchor in cortical bone are longer than conventional implants. Because heating can be related to length, if you have an implant of this type, and particularly if the scan is going to be carried out in a powerful scanner, it is useful to tell the radiology team the type and length of the implant. The scanners used in day-to-day hospital practice are mostly 1.5 and 3 Tesla.
Image distortion is the real practical issue. The FDA writes that implants can distort or interfere with MRI and X-ray images. Metal warps the magnetic field around it and creates distortions (artefacts) that appear in the image as a void or a bright area. In a study carried out in Denmark, titanium created more magnetic field distortion and image distortion than zirconia. The field distortion grew as scanner strength increased; this measurement was made at 0.55, 1.5 and 3 Tesla in an artificial model (phantom). The scan in a volunteer was carried out at 0.55 Tesla only, and the distortion was seen mostly in the crown area close to the implant. In a study carried out in Germany on dry lower jawbones, too, the volume of distortion was largest with the combination of a titanium implant and a cobalt-chromium crown, and smallest with a zirconia implant and a ceramic crown.
How far this distortion affects the diagnosis of the brain or the neck is not fully known. A systematic review that examined nineteen studies writes that in MRI of the head and neck the most distortion is caused by stainless steel orthodontic brackets, while for implants and prostheses the data are insufficient and inconclusive. The review states that distortion can affect the diagnosis of brain and facial structures as well as the oral cavity, and that its severity depends on the material, the position in the mouth and the scan settings. In an MRI scan of the knee or the lower back, an implant is not expected to affect the image; the issue is scans of the head, face and neck.
Magnetic dentures are a separate topic. Some removable dentures hold on to a stainless steel keeper screwed onto the implant by means of a small magnet inside the denture. This steel part, unlike titanium, is strongly pulled by the magnetic field of MRI: in tests carried out at 7 Tesla the deflection angle exceeded 90 degrees; in the 3 Tesla tests, too, all the deflection angles exceeded 45 degrees. By contrast, in a measurement made in Japan at 1.5 and 3 Tesla, the force acting on the keeper stayed far below the bonding force that fixes the keeper to the root cap. This measurement was made with keepers bonded to a natural tooth root; it cannot be transferred directly to a keeper screwed onto an implant. In the 3 Tesla tests, heating was measured at below 1.5 degrees. The authors of the 3 Tesla study, however, write that the deflection forces tended to exceed the acceptable limit, and for safety they recommend that magnetic attachments be inspected before and after the scan.
The magnet itself can be affected too. In a study carried out in a 3 Tesla scanner, when the magnets inside the denture entered and left the scanner at a certain angle, their magnetic strength fell significantly and retention dropped. For this reason the authors recommend that magnetic removable dentures be taken out before an MRI scan. Removing large prostheses made of cast alloys that contain a magnet is also recommended. In practice this means: take the denture out and leave it outside the MRI room, and tell the team about the steel keeper on the implant and that the denture is magnetic.
When nothing extra is needed, and when the team should be told separately
In the situations in the first list, stating your implant on the form is enough. In the situations in the second list, the radiology team knowing in advance may call for preparation or an adjustment of the scan settings.
When it fits
- A titanium implant with fixed teeth screwed or cemented onto itNo problem is reported in terms of being pulled or heating. State your implant and your fixed prosthesis on the form; the NHS form completed before an MRI scan asks about metal parts in the body, including fillings and bridges.
- MRI of areas other than the jaw and faceIn an MRI scan of the lower back, knee, abdomen or shoulder, an implant is not expected to affect the image. Report it all the same; this is part of the team's routine safety questioning.
- A zirconia implantIn studies it created less image distortion in MRI than titanium. Because it is ceramic, the question of being pulled and of heating does not arise either; state it on the form all the same.
- Conventional CT and dental X-raysAn implant is no obstacle to these investigations. The FDA writes that an implant can interfere with the X-ray image too; this is a matter of image quality, not of safety.
When it doesn't
- A removable denture held in place by a magnetTake the denture out before the scan. The stainless steel keeper on the implant is strongly pulled by the magnetic field; the team needs to know this, and it needs to be checked that the keeper is firmly seated.
- MRI of the brain, face, sinuses, jaw joint or neckBecause an implant, and especially a metal crown or bridge, is close to the area being scanned, it can create distortion in the image. The radiologist can choose the scan settings accordingly; so say it in advance.
- Zygomatic or very long implantsHeating was measured as more pronounced in long implants. Tell the team the type and length of the implant, especially with scanners of 3 Tesla and above.
- A prosthesis with a metal framework containing cobalt-chromium or nickel-chromiumThese alloys showed more pronounced deflection in the magnetic field and more image distortion than titanium. If you do not know what your prosthesis is made of, ask your dentist.
- A feeling of heating, pulling or pain in the mouth during the scanLet the team carrying out the scan know straight away; use the call button you are given inside the scanner. This is sufficient reason for the scan to be stopped and assessed.
How to prepare for an MRI appointment with implants
The steps below are for everyone who has an implant. If the hospital has its own instructions, those apply.
- 1
Get your implant details and keep them
The FDA recommends that you ask your dentist for the brand and model of the implant and keep this information in your records. Keep the number of implants, their type (conventional, zygomatic, strategic), their material and the type of prosthesis on top on a card or on your phone.
- 2
Say so when you book the appointment
When you book the MRI appointment, state that you have implants and a fixed or removable prosthesis in your mouth. Particularly if a scan of the head and neck is going to be carried out, this information helps the team choose the appropriate scanner and scan settings.
- 3
Fill in the safety form in full
The form completed before an MRI scan, as the NHS describes it, asks about your surgical history and about metal parts in the body, including fillings and bridges. Write your implant, your prosthesis and, if you have one, the magnetic keeper on this form.
- 4
Take out your removable denture
The NHS asks for jewellery and items containing metal to be removed. Take out your removable denture before the scan, especially if it is magnetic, and leave it in a safe container outside the room. Fixed teeth and the implant stay in place.
- 5
During the scan
If you feel heating, pulling or discomfort in your mouth during the scan, let the team know. The NHS writes that in scans where a contrast agent is given there can be a metallic taste in the mouth; this has nothing to do with the implant.
- 6
A check after the scan with a magnetic denture
The authors of the studies recommend that magnetic attachments be inspected before and after the scan. If the denture's retention has fallen after the scan, show it to your dentist; the strength of the magnet may have decreased.
The effect of an implant by type of imaging
Each imaging method interacts with an implant differently. The comparison below shows what to watch for in which investigation.
MRI
A titanium implant is not pulled, and heating is small in measurements. In images of the head and neck, titanium creates more distortion than zirconia, and the distortion increases with scanner strength.
Dental cone beam CT
Here the picture is reversed: in a study carried out on pig jaws by researchers from Switzerland and Brazil, an implant lowered image quality when it lay just outside the field of view, and the greatest effect came from zirconia implants, followed by titanium-zirconium alloy and titanium.
Medical CT and X-rays
An implant is no obstacle to these investigations; the FDA writes that implants can distort the X-ray image too. Implant check-up X-rays are, after all, taken in order to see the implant.
Airport security checks
The US Transportation Security Administration (TSA) writes that people with metal implants should tell the officer, and that additional screening will be carried out if the walk-through detector alarms. We could not find a study measuring how often dental implants set off the security detector; tell the officer about your implant before screening; if the detector goes off, according to the TSA a pat-down is carried out.
A removable denture with another type of attachment instead of a magnetic one
For someone with a condition that requires frequent MRI scans, this too can be discussed when the denture attachment is being chosen. We have explained the attachment options for removable implant-retained dentures and the differences in complications on our page on removable implant-retained dentures.
Common mistakes about MRI and implants
The following are decisions that lead to unnecessary worry or to an avoidable problem.
Giving up a necessary MRI scan because you have an implant
A titanium implant is no obstacle to MRI. The FDA writes that it is not aware of any reported adverse event related to MRI or X-rays. Postponing a necessary investigation because of an implant delays the diagnosis of the actual illness.
Not writing the implant on the form
An implant that has not been reported can lead to a distortion in an image of the brain or face being misinterpreted. A radiologist who knows in advance recognises the distortion and changes the settings if necessary.
Going into the scan with a magnetic denture
The magnet can weaken in a strong field and the denture can lose its retention. There is no benefit whatsoever in taking a removable denture into the scan.
Trying to take out fixed teeth
Screwed or cemented fixed teeth are not removed by the patient and do not need to be removed for MRI. It is enough for the radiology team to know.
Confusing CT with MRI
CT uses X-rays, MRI a magnetic field. In both, an implant can affect the image, but in different ways; the safety question arises only in MRI, for magnetic parts.
Before and after the scan, step by step
The sequence below is for a typical MRI appointment; the hospital's instructions take priority.
When you book the appointment
Give the details of the implant, the type of prosthesis and, if you have one, the magnetic keeper. If it is a scan of the head and neck, stress this in particular.
On the day of the scan, beforehand
Fill in the safety form, and take off metal items and take out your removable denture. Fixed teeth and implants stay in place.
During the scan
If you feel heating or pulling in your mouth, let the team know with the call button. Heating was found to be small in measurements, but saying something you feel is always right.
After the scan
Put your magnetic denture in and check its retention. The NHS writes that results usually arrive within 1 to 2 weeks; if the report has a note of distortion in the jaw area, this is most often the expected effect of the implant.
Don't wait if
- If the retention of your magnetic denture has fallen after an MRI scan. Show it to your dentist; the strength of the magnet may have decreased or the keeper may have shifted.
- If you have noticed movement or pain in the implant after an MRI scan. This is not an expected effect of MRI. See your dentist; screw loosening or another problem is assessed separately.
- If the radiologist has asked about the type or material of the implant. Ask the clinic that placed the implant for the implant card or for the brand, model and material details.
- If you have a condition that requires frequent MRI scans and a new prosthesis is being planned. Tell your dentist this when the denture attachment and the crown material are being chosen.
What makes a difference on the MRI and implant side
An implant does not change the MRI scan itself. But the preparation and the quality of the image are determined by these factors:
- The area to be scanned
- In scans of the head, face and neck, the implant's effect on the image matters; in other areas of the body no effect is expected.
- Implant and prosthesis material
- Titanium, zirconia and cobalt-chromium create different levels of image distortion.
- How the prosthesis is held in place
- Magnetic attachments require additional reporting and a check after the scan; screwed or cemented fixed teeth do not.
- The strength of the scanner
- Image distortion and measured heating increase from 1.5 Tesla towards 3 and 7 Tesla.
Frequently asked questions
Can you have an MRI scan with dental implants?
Yes. A titanium implant is not pulled by a magnet, and in measurements heating stayed below half a degree in 1.5 and 3 Tesla scanners. The FDA recommends that you tell the healthcare team about your implant before the scan.
Does an implant heat up during an MRI scan?
Very little in measurements. In tissue-like models, a rise of 0.4 degrees at most was measured in titanium implants. In a 7 Tesla research scanner, the rise reached as much as 1.5 degrees in an implant 50 mm long. If you feel heating during the scan, tell the team.
Does an implant distort the MRI image?
It can in scans of the head, face and neck. The FDA writes that implants can distort MRI and X-ray images. Titanium creates more distortion than zirconia, and the effect grows as scanner strength increases. In an MRI scan of the knee or the lower back, no effect is expected.
I have a magnetic denture; can I go into an MRI scanner?
You can, but take the denture out beforehand. Studies have shown that magnets can weaken in a strong field. The stainless steel keeper on the implant is strongly pulled by the magnetic field; tell the team, so that it is checked before and after the scan that the keeper is secure.
Do I need to mention my implant for a brain MRI scan?
Yes. Because images of the brain and face are close to the mouth, implants and metal crowns can create distortion in the image. A radiologist who knows in advance can choose the scan settings accordingly.
Is there a difference with a contrast MRI scan, that is, one with a dye?
Not as far as the implant is concerned. The form the NHS describes asks separately about kidney problems and allergy to the contrast agent; these questions have nothing to do with the implant.
Can you have an MRI scan with zygomatic implants?
Titanium zygomatic implants are no obstacle to MRI either. Because heating was measured as a little more pronounced in long implants, tell the team the type and length of the implant, especially with powerful scanners.
Will the detector go off at the airport because of an implant?
We could not find a study measuring how often dental implants set off the detector. The TSA writes that people with metal implants should tell the officer, and that additional screening will be carried out if there is an alarm. If the detector goes off, mention your implant.
Does an implant cause a problem in a CT scan?
It is no obstacle to a CT scan, but it can affect image quality. In dental CT, zirconia implants have been shown to affect the image more than titanium; in MRI it is the reverse, titanium creates more distortion.
Sources
- U.S. Food and Drug Administration (FDA)Dental Implants: What You Should Know
- NHSMRI scan
- Transportation Security Administration (TSA)Disabilities and Medical Conditions
- Nihon Hoshasen Gijutsu Gakkai Zasshi (PubMed)[Investigation of radio frequency heating of dental implants made of titanium in 1.5 tesla and 3.0 tesla magnetic resonance procedure: measurement of the temperature by using tissue-equivalent phantom].
- Clinical Oral Implants Research (PubMed)Evaluation of Exomass-Related Artefacts Caused by Dental Implants of Different Materials in Cone-Beam Computed Tomography Scans: An Ex Vivo Study.
- Magnetic Resonance in Medical Sciences (PubMed)Impact of the Static and Radiofrequency Magnetic Fields Produced by a 7T MR Imager on Metallic Dental Materials.
- Journal of Magnetic Resonance Imaging (PubMed)Magnetic displacement force and torque on dental keepers in the static magnetic field of an MR scanner.
- Dentomaxillofacial Radiology (PubMed)Interference of titanium and zirconia implants on dental-dedicated MR image quality: ex vivo and in vivo assessment.
- Journal of Prosthetic Dentistry (PubMed)Artifacts in magnetic resonance imaging of the head and neck: Unwanted effects caused by implant-supported restorations fabricated with different alloys.
- Dentomaxillofacial Radiology (PubMed)Artifacts in magnetic resonance imaging caused by dental materials: a systematic review.
- Dentomaxillofacial Radiology (PubMed)3-T MRI safety assessments of magnetic dental attachments and castable magnetic alloys.
- Radiological Physics and Technology (PubMed)Magnetization and demagnetization of magnetic dental attachments in a 3-T MRI system.
Related pages
- Implants and Your HealthAre Implants Harmful? Titanium Allergy, MRI and CancerTitanium allergy, MRI, cancer and heart questions: which have a real basis and which are myths. The genuine risks of surgery, with sources.
- Life After TreatmentFlying, Travel and Sport After ImplantsWhen you can fly, whether airport scanners go off, MRI scans, returning to sport, and why diving is a separate question. Planning travel correctly.
- Living with DenturesSnap-On Dentures: How Many Implants, and What Upkeep?An implant-retained denture on two implants is the standard in the lower jaw. Locator, ball and bar attachments, insert replacement and fixed teeth compared.
- The ProcessWhy a CBCT Scan Before Dental Implants?A panoramic X-ray only shows bone height. We explain what a CBCT scan shows instead, its radiation dose, and what to do if you are pregnant or have an old scan.
- Compare Your OptionsWhat Are Zygomatic Implants, and Who Are They For?How zygomatic implants help with severe bone loss in the upper jaw, how they compare with a sinus lift and graft-free placement, and what the evidence shows.
- The ProcessHow Long Does a Dental Implant Last, and Why?The implant and the bridgework on it do not last equally long. What determines lifespan, peri-implantitis, daily care, and what is done if a problem appears.
- The ProcessHow Do You Look After Teeth on Implants?Why cleaning under a fixed bridge differs from natural teeth, how to use an interdental brush and water flosser, and the sign that reveals peri-implantitis.
- The ProcessBruising After Dental Implants: How Long Does It Last?How much facial bruising is normal after implants or an extraction, how long it takes to fade, what blood thinners change and when swelling means 112.
- The ProcessStitches After Dental Implants: Dissolving and RemovalHow many days implant stitches take to dissolve, when non-dissolvable ones are removed, what it means if they come apart or you see white tissue, and cleaning.
Send your X-ray and we will tell you which option is realistic for your tooth.
Get an assessmentNext step
Send your X-ray and we will talk through the options.
Share your CBCT or panoramic X-ray. We will write back within 24 hours on which option is realistic for your tooth.